Substituição Chamber Exhuast Ventilador / Cooler
Bambu Lab H2S • Série Comercial H2
Substituição Chamber Exhuast Ventilador / Cooler
Note: This page uses the H2D machine as an example. The replacement Steps are exactly the same for the H2S and H2C.
Chamber Exhaust Fan
The chamber exhaust fan is installed on the right inner lining of the printer, behind the activated carbon air filter, and is used to vent air from inside the printer to the outside.
The spare parts for the chamber exhaust fan include the following:
-
Chamber exhaust fan * 1
-
Active chamber exhaust * 2
-
Soft screws * 4

When to Use
-
Fan is squeak
-
Fan is damaged
Tools and Materials Needed
-
New chamber exhaust fan
-
H2.0 Allen key
Specifications and quantities of screws involved in replacing the H2D chamber exhaust fan (it is recommended to keep the removed screws properly to avoid loss):
| Specification | Image | Use | Position | Quantity | |
|---|---|---|---|---|---|
| BT3x8 | Fix the rear panel (marked by the green square) | ![]() |
12 | ||
| Fix the purge chute | ![]() |
1 | |||
| ST3x8 | Fix the rear panel (marked by the red circle) | ![]() |
11 | ||
| ST3x12 | Fix the spool holder bracket (marked by the yellow square)) | ![]() |
2 |
Aviso de Segurança
IMPORTANT!
It’s crucial to power off the printer before conducting any maintenance work, including work on the printer’s electronics and tool head wires. Performing tasks with the printer on can result in a short circuit, leading to electronic damage and safety hazards.
During maintenance or troubleshooting, you may need to disassemble parts, including the hotend. This exposes wires and electrical components that could short circuit if they contact each other, other metal, or electronic components while the printer is still on. This can result in damage to the printer’s electronics and additional issues.
Therefore, it’s crucial to turn off the printer and disconnect it from the power source before conducting any maintenance. This prevents short circuits or damage to the printer’s electronics, ensuring safe and effective maintenance. For any concerns or questions about following this guide, we recommend submitting a chamado técnico relatando o seu problema. and we will do our best to respond promptly and provide the assistance you need.
Remove the Chamber Exhaust Fan
Passo 1: Remove the rear panel cover and purge chute
You can refer to this Wiki to remove the panel cover and purge chute:
Passo 2: Remove the active chamber exhaust
Carefully remove the active chamber exhaust. If it is damaged, use the spare exhaust. You can refer to this Wiki for removal:
Replace H2D Active Chamber Exhaust
Passo 3: Remove the activated carbon air filter cover and activated carbon air filter
Since the soft screws need to be secured from this side later on, you can refer to this Wiki to remove the activated carbon air filter cover and activated carbon air filter:
Replace H2D Activated Carbon Filter Cover/Activated Carbon Filter
Passo 4: Remove the chamber exhaust fan
- First, disconnect the chamber exhaust fan connector from the MC board, and remove the cable from the cable clip.


- The chamber exhaust fan is fixed to the right inner lining with soft screws. You can firmly pull the fan out. After removal, take out the soft screws remaining on the inner lining.


Soft screw may vary in color; this is normal and does not affect installation or performance.
Install the Chamber Exhaust Fan
Passo 1: Install the chamber exhaust fan
- Take out the four soft screws and cut the end off one of them.

- Pre-install the soft screws onto the three corners of the chamber’s exhaust fan.

- Install the trimmed soft screw in the lower-left corner of the liner.

- Check the cable positions to avoid incorrect fan orientation.

- Then, pull the screws on the printer into the chamber’s exhaust fan by pulling the screws and pushing the fan inward, ensuring the screws securely fasten the fan.

- You can gently push the wind deflector to pull out the screw, then insert it into the mounting hole from the side.
If you find that the head of the soft screw is too short to handle easily, you can use tools such as tweezers to assist with the installation.
First, pull the soft screw in the lower-right corner to snap it into the clip on the liner. Then, install the soft screws in the lower-left, upper-right, and upper-left corners in sequence.
| the yellow soft screw | ![]() |
![]() |
| the white soft screw | ![]() |
![]() |
- Pass the cable through the notch on the inner lining, then secure it into the cable clips in sequence, and finally connect it to the MC board.


Passo 2: Install the purge chute and rear panel
You can refer to the following Wiki to install the purge chute and rear panel:
Passo 3: Install the active chamber exhaust
You can refer to the following Wiki to install the active chamber exhaust:
Replace H2D Active Chamber Exhaust
Passo 4: Install the activated carbon air filter cover and activated carbon air filter
You can refer to the following Wiki to install the activated carbon air filter cover and activated carbon air filter:
Replace H2D Activated Carbon Filter Cover/Activated Carbon Filter
Verify the Functionality
Connect the power and turn on the printer, and check that the chamber exhaust fan operates normally.
Notas Finais
Esperamos que o guia detalhado fornecido tenha sido útil e informativo.
If this guide does not solve your problem, please submit a chamado técnico, we will answer your questions and provide assistance.
If you have any suggestions or feedback on this Wiki, please leave a message in the comment area. Thank you for your support and attention!