Flow Blocker Replacement Guide
Bambu Lab H3C • Série Industrial H3
Flow Blocker Replacement Guide
Flow Blocker Assembly
The complete Flow Blocker Assembly includes the Flow Blocker Pad and its mount. In the actual accessory package, there is a mount without the Flow Blocker Pad and 5 Flow Blocker Pads.

When to Replace
- The pad is damaged and affects usability, requiring replacement of the Flow Blocker Pad.
- The Flow Blocker Mount is damaged and requires replacement of the mount.
Tools and Materials
- H1.5 Allen Key
Safety Tips
Before performing any maintenance on the printer and its electronic components (including the Toolhead Cable), turn off the printer and disconnect the power supply to prevent accidental Screen touches or short circuits, which could cause additional electronic damage and safety hazards.
When performing maintenance or troubleshooting on your printer, please first check the temperature of the hotend and heatbed. Avoid operating at high temperatures. If operating at high temperatures is unavoidable, wear insulated gloves to ensure safe and effective maintenance.
Remove Flow Blocker Assembly
Passo 1: Remove the PrintTool
Hold the upper part of the PrintTool assembly with your hand, lift it diagonally upwards, and detach the corresponding PrintTool assembly.

Passo 2: Remove the Flow Blocker Pad (Applicable when the Flow Blocker Pad is damaged)
Simply pull off the damaged Flow Blocker Pad by hand.
![]() |
![]() |
Passo 3: Remove the Flow Blocker Mount (Applicable when the Flow Blocker Mount is damaged)
Using an H1.5 allen key, remove the 2 screws and detach the Flow Blocker Assembly.
![]() |
![]() |
How to Install the Flow Blocker Assembly
Passo 1: Install the Flow Blocker Pad onto the Mount (Applicable when only replacing the Flow Blocker Pad)
Align the pins on the Flow Blocker Pad with the mounting holes on the mount, then place the pad and press down to extend the pins further downwards.
![]() |
![]() |
Install the pins of the pad one by one by hand, then stretch the pins and cut them below the nodes with scissors.
![]() |
![]() |
Passo 2: Install the Flow Blocker Mount (Assembly) onto the bracket (Applicable when replacing the mount)
Install the new Flow Blocker Pad onto the mount, then install the mount onto the bracket, secure with 2 screws, and trim the excess pad pins.
![]() |
![]() |
Passo 3: Nest the PrintTool
Retract the PrintTool into the printer chamber. First, align it with the orange installation guide slot, then let the magnets pull it into place and nest it onto the hanger.
![]() |
![]() |
Verify Functionality
Conclusion
We hope this guide provides you with clear and practical assistance.
If the problem persists, please submit a service ticket with your recent device logs, relevant photos, or other detailed information. Our customer support team will be ready to answer your questions and provide support.
You can also visit Bambu AI, which can instantly answer common questions and provide operational guidance.
(Note: May contain AI-generated content)
Notas Finais
We hope this guide has provided clear and practical support.
If the issue remains unresolved, please submit a support ticket and include your recent printer logs and additional pictures or other details. Our customer support team will review your request and provide detailed assistance.
You can also visit Bambu AI, which can instantly answer common questions and provide you with operational guidance.