The nozzle offset calibration sensor is installed at the rear of the heatbed and is used to calibrate the positions of different print tools, ensuring good print quality.
22_nozzle_offset_calibration_sensor_replacement_guide_b8a5c67992.png

When to Replace

  • The nozzle position is offset, causing model misalignment and layer shifting during printing. This cannot be recovered even with nozzle offset calibration.
  • The structural component is damaged, leading to calibration failure.
  • Bambu Lab official technical support has confirmed that the nozzle offset calibration sensor needs to be replaced.

Tools and Materials

  • H2.0 allen key

Safety Tips

Before performing any maintenance on the printer and its electronic components (including the Toolhead Cable), turn off the printer and disconnect the power supply to prevent accidental Screen touches or short circuits, which could cause additional electronic damage and safety hazards.
05_side_panel_left_replacement_guide_8c09dac0a4.png

When performing maintenance or troubleshooting on your printer, please first check the temperature of the hotend and heatbed. Avoid operating at high temperatures. If operating at high temperatures is unavoidable, wear insulated gloves to ensure safe and effective maintenance.

Remove the Nozzle Offset Calibration Sensor

Passo 1. Raise the Heatbed (optional, for easier operation)

Perform a homing operation to raise the heatbed to a higher position, then turn off the printer.
Manually move the toolhead to the purge wiper assembly location and remove the build plate (if applicable).
22_nozzle_offset_calibration_sensor_replacement_guide_546e4f8d39.png

Passo 2. Remove the Screws

Use an H2.0 allen key to remove the two screws and take off the wiper steel piece on the right.

22_nozzle_offset_calibration_sensor_replacement_guide_b7c9dea627.png 22_nozzle_offset_calibration_sensor_replacement_guide_ad29e50a4f.png

Passo 3. Remove the Nozzle Offset Calibration Sensor

Gently lift the nozzle offset calibration sensor and rotate it to expose the connector. Press the connector’s locking tab with a wrench to unlock it, then remove the nozzle offset calibration sensor.

22_nozzle_offset_calibration_sensor_replacement_guide_899b907d6f.png 22_nozzle_offset_calibration_sensor_replacement_guide_cf740748c4.png

Install the Nozzle Offset Calibration Sensor

Passo 1. Connect the Nozzle Offset Calibration Sensor

As shown, orient the connector towards the heatbed and connect the cable. The locking tab should be facing down. Then, flip the nozzle offset calibration sensor and install it onto the bracket.

22_nozzle_offset_calibration_sensor_replacement_guide_5ccd4f6930.png 22_nozzle_offset_calibration_sensor_replacement_guide_8deb67aea2.png

Passo 2. Secure the Screws

First, secure the screw on the left. Then, install the wiper steel piece on the right and secure its screw.

22_nozzle_offset_calibration_sensor_replacement_guide_938515e854.png 22_nozzle_offset_calibration_sensor_replacement_guide_cc0dadae68.png

Verify Functionality

Turn on the printer, place the build plate, and perform a nozzle offset calibration. The calibration should succeed.