Substituição Purifier Front Cover
Bambu Lab H3C • Série Industrial H3
Substituição Purifier Front Cover
E1 Front Cover

When to Replace
- The screen is damaged or the display is abnormal.
- The front cover assembly is damaged or deformed.
Safety Tips
Before performing any maintenance on the air purifier and its electronic components, power off the device and disconnect the power supply to prevent circuit shorts, which can cause additional device damage and safety risks. Before maintenance or troubleshooting, please ensure that the relevant parts have cooled down.
Tools and Materials
- H2.0 Allen key
- H1.5 Allen Key
Remove the E1 Front Cover
Passo 1. Remove the Filter Element
Disconnect the air duct connected to the purifier, the Power Cable, and the 6-pin cable (if any).

Slide the rear cover upwards to remove it.

Take out the filter element handle, pinch the handle, and pull out the filter element.

Passo 2. Separate the Front and Rear Housings
Peel off the three foam strips as shown.
![]() |
![]() |
![]() |
Turn the device over and remove the footpads from the front housing.

Use an H2.0 Allen key to remove the two screws.

Use an H2.0 Allen key to remove the seven screws shown.

Separate the front and rear housings, then disconnect the connecting cables between them.

Passo 3. Remove the E1 Button Assembly with Chamber Temperature Sensor, Mainboard, and Fan
Disconnect the three connectors shown.
![]() |
![]() |
Use an H2.0 Allen key to remove the two screws, then remove the button board with the chamber temperature sensor.

Use an H1.5 Allen key to remove the single screw and disconnect the Screen ground wire.

Use an H1.5 Allen key to remove the remaining three screws, then remove the mainboard.

Use an H2.0 Allen key to remove the three screws, then remove the fan.

At this point, all other components on the front cover have been completely disassembled. Please refer to the installation steps to reassemble the components onto the new front cover assembly.
Install the E1 Front Cover
Passo 1. Install E1 Fan, Mainboard, and Button Board with Chamber Temperature Sensor
Reinstall the fan and secure it with the three screws using an H2.0 Allen key.

Reinstall the E1 mainboard and secure the three screws with an H1.5 Allen key.

Reinstall the screen ground wire and secure it with one screw using an H1.5 Allen key.

Reinstall the button board with the chamber temperature sensor and secure it with the two screws using an H2.0 Allen key.

Reinstall the fan, Button board with Chamber Temperature Sensor, and the screen connector cable plug.

Passo 2. Install the Front and Rear Housings
Connect the three plugs as shown, then close the front and rear housings.

Use an H2.0 Allen key to secure the seven screws.

Turn the device upside down and use an H2.0 Allen key to secure the two screws.

Attach the footpads.

Attach the foam strips around the filter element.

Passo 3. Install the Filter Element
Install the filter element, ensuring the handle side faces outwards.

Tuck the filter element handle into the filter mesh to avoid obstructing the rear cover installation.

Install the rear cover.

Reinstall the purifier air duct, Power Cable, and 6-pin cable (if any).

Verifying Functionality
After the replacement is complete, confirm that the front cover is securely installed, the locking tabs are in place, and it fits snugly with the main body without any noticeable gaps. Start the purifier and confirm that it operates normally, with no looseness, abnormal noise, or unusual vibrations coming from the front cover.
Notas Finais