Substituição Purifier Main Board
Bambu Lab H3C • Série Industrial H3
Substituição da Placa Principal do Purificador E1 / H3C
¶ E1 Mainboard

¶ Safety Tips
Before performing any maintenance on the air purifier and its electronic components, power off the device and disconnect the power supply to prevent circuit shorts, which can cause additional device damage and safety risks. Before maintenance or troubleshooting, please ensure that the relevant parts have cooled down.
¶ Tools and Materials
- H2.0 Allen key
- H1.5 Allen Key
¶ Remove the E1 Mainboard
¶ Passo 1. Remove the Filter Element
Disconnect the air duct connected to the purifier, the Power Cable, and the 6-pin cable (if any).

Slide the rear cover upwards to remove it.

Take out the filter element handle, pinch the handle, and pull out the filter element.

¶ Passo 2. Separate the Front and Rear Housings
Peel off the three foam strips as shown.
![]() |
![]() |
![]() |
Turn the device over and remove the footpads from the front housing.

Use an H2.0 Allen key to remove two screws.

Use an H2.0 allen key to remove the seven screws as shown.

Separate the front and rear housings, then disconnect the connecting cables between them.

¶ Passo 3. Remove the E1 Mainboard
Unplug the three plugs as shown.
![]() |
![]() |
Use an H1.5 Allen key to remove the single screw and disconnect the Screen ground wire.

Use an H1.5 Allen key to remove the remaining three screws and take off the mainboard.
![]() |
![]() |
¶ Install the E1 Mainboard
¶ Passo 1. Install the E1 Mainboard
Reinstall the E1 mainboard and secure the three screws with an H1.5 Allen key.

Reinstall the Screen ground wire①, and secure it with the single screw ① using an H1.5 Allen key. Then, reconnect the three plugs as shown (②-④).

¶ Passo 2. Install the Front and Rear Housings
Connect the three plugs as shown, then close the front and rear housings.

Use an H2.0 allen key to secure the seven screws.

Turn the device upside down and use an H2.0 allen key to secure two screws.

Attach the footpads.

Attach the foam strips around the filter element.

¶ Passo 3. Install the Filter Element
Install the filter element, ensuring the handle side faces outwards.

Tuck the filter element handle into the filter mesh to avoid obstructing the rear cover installation.

Install the rear cover.

Reinstall the purifier air duct, Power Cable, and 6-pin cable (if any).

¶ Verifying Functionality
After completing the replacement, reconnect the power supply and turn on the purifier. Verify that the device powers on normally and that the display and buttons function correctly.
¶ Notas Finais
We hope this guide has provided clear and practical support.
If the issue remains unresolved, please submit a support ticket and include your recent printer logs and additional pictures or other details. Our customer support team will review your request and provide detailed assistance.
You can also visit Bambu AI, which can instantly answer common questions and provide you with operational guidance.