Chamber Temperature Sensor Replacement Guide for the P2S
Bambu Lab P2S • Série Performance P2
Chamber Temperature Sensor Replacement Guide for the P2S
Chamber Temperature Sensor
The chamber temperature sensor is an NTC with a fixed bracket, installed on the inside of the printer’s front beam, and is used to detect the temperature inside the printer chamber.
Accessory package includes:
- Chamber temperature sensor* 1
- BT3x6 screw* 2
When to Use This Guide
- The chamber temperature sensor connection cable is damaged.
- Chamber temperature error.
Required Tools and Materials
- New chamber temperature sensor
- H2.0 Hex wrench
Aviso de Segurança
IMPORTANT!
Always power off and disconnect power on the printer before performing maintenance work. Not doing so means there is a risk of electric shock, short circuit, and damage to the printer or surrounding area.
When a maintenance task necessitates the printer being powered on, use insulated gloves for safety and pay special care not to pinch, damage, or put pressure on any exposed wires, connectors, or circuit boards. Additionally, the nozzle can be extremely hot so never touch it with exposed skin.
If you have any questions or concerns related to the above or the steps in this guide, please open a new ticket in our Support Page for assistance.
Remove the Chamber Temperature Sensor
Passo 1: Disconnect the Cables
Open the access end of the AP board cover, then disconnect the chamber temperature sensor cable from the AP board.
![]() |
![]() |
Passo 2: Remove the Chamber Temperature Sensor
Locate the chamber temperature sensor inside the front cross beam. Remove the two screws (BT3x6) with an H2.0 Allen key, then remove the sensor.
![]() |
![]() |
Install the Chamber Temperature Sensor
Passo 1: Install the Chamber Temperature Sensor
Align the new chamber temperature sensor with the screw holes on the printer beam, and tighten the two fixing screws (BT3x6) using an H2.0 Allen key.
Please hold the chamber temperature sensor in place while tightening the first screw, then tighten both screws together.
![]() |
![]() |

Passo 2: Connect the Cables
Route the chamber temperature sensor cable along the cross beam to the side of the AP board, connect it to the AP board, and refasten the inspection end of the AP board cover.
![]() |
![]() |

Verifying Functionality
Connect the power supply and turn on the printer, then check whether the chamber temperature is normal.
Notas Finais
We hope this guide has provided clear and practical support.
If the issue remains unresolved, please submit a support ticket and include your recent printer logs and additional pictures or other details. Our technical team will review your request and provide detailed assistance.
You can also visit Bambu AI, which can instantly answer common questions and provide you with operational guidance.