Overview

The eddy sensor on the toolhead handles tasks like Z-axis homing, bed leveling, and flow dynamics calibration. If the distance between the eddy sensor and the nozzle is too short or too long, these functions may be affected.

If the gap is too large or too small, the device may register Eddy sensor signal frequency is too low” and “Sensitivity is too low”. Follow the steps below to adjust the eddy sensor and get the printer back to normal operation.

Video Guide

This article focuses on the right hotend as the primary operation object, and the video includes adjustments for the left hotend.

Adjustment Steps

Passo 1. Remove the Toolhead Front Cover

Lift the toolhead front cover assembly and secure it above the toolhead to expose the hotend for easier access during subsequent operations.

Passo 2. Perform a Quick Check of the Eddy Sensor gap

Cut a strip of A4 paper approximately 4 mm × 60 mm, then fold it once. Insert the paper strip between the nozzle and the eddy sensor, and gently slide it back and forth to test.

Judging criteria:

  • If the paper strip is too tight to move, the gap is too small.

  • If the paper strip moves with almost no resistance, the gap is too large.

  • Ideally, you should feel slight friction, but the paper should still move freely. This indicates the gap between the nozzle and the eddy sensor is approximately 0.2–0.3 mm.

Passo 3. Remove the Hotend Assembly

If an abnormal gap is detected, first remove the hotend assembly, then adjust the position of the eddy sensor.

Passo 4. Adjust the Position of the Eddy Sensor

Use an H2.0 Allen key to loosen the two screws fixing the eddy sensor (no need to fully remove them).

Left eddy sensor fixing screws are as follows:
pixpin_2026-05-20_11-25-02.jpg

Use tweezers to gently move the eddy sensor, adjusting its distance from the nozzle. Afterward, use an H1.5 hex screwdriver to retighten the screws.

Passo 5. Reinstall the Hotend Assembly

Reinstall the hotend assembly into the toolhead and ensure the locking tabs are fully secured in place.

Passo 6. Confirm the Gap Again

Use the folded A4 paper strip again to test the gapbetween the nozzle and eddy sensor. If you feel slight friction while the paper moves smoothly, the gap is properly adjusted (around 0.2–0.3 mm).

Verifying Success

✅ To verify normal operation, power on the printer and perform a bed leveling calibration. If no zeroing or leveling errors occur during the process, the distance between the eddy sensor and the hotend is within the acceptable range.

auto_bed_calibration.png

Notas Finais

We hope this guide has provided clear and practical support.
If the issue remains unresolved, please submit a support ticket and include your recent printer logs and additional pictures or other details. Our technical team will review your request and provide detailed assistance.
You can also visit Bambu AI, which can instantly answer common questions and provide you with operational guidance.